1.
Chinese Journal of Clinical Laboratory Science ; (12): 241-245, 2019.
Article in Chinese | WPRIM | ID: wpr-821711

ABSTRACT

Objective@#To develop and evaluate a beads-based light-initiated chemiluminescent assay (LICA) for quantitation of cow milk component (Bos d 5) specific IgG 4 antibody in human serum. @*Methods@#The sIgG 4 -LICA was performed by incubated serum samples with biotinylated allergens, emission beads coated with mouse anti-human IgG 4 antibody and streptavidin-coated sensitizer beads. The reaction conditions of sIgG 4 -LICA were optimized and the analytical performance was evaluated. @*Results@#The precision of intra-assay, within-day and inter-assay (coefficient of variation) were 1.78% to 3.13%, 6.65% to 8.41% and 7.94% to 12.30%, respectively. The functional sensitivity of this assay was 4.71 ng/mL. For the linear range, the sIgG 4 -LICA had a good linear relationship within the range between 28.13 and 1 800 ng/mL, and the linear regression equation was Y=0.98X-1.31(r 2 =0.997). Maximum dilution limit was 1∶64. The disturbing rates measured by adding hemoglobin, triacylglycerol, total bilirubin, acid resistance and biotin to human sera with different concentrations of Bos d 5 sIgG 4 were from -6.38% to 8.60%. @*Conclusions@#The sIgG 4 -LICA introduced in this study was demonstrated to have effective performance for quantitation of allergen-specific IgG 4 and can meet the need of clinical requirement.

2.
Chinese Journal of Clinical Laboratory Science ; (12): 1-4,13, 2018.
Article in Chinese | WPRIM | ID: wpr-694796

ABSTRACT

Objective To develop a competitive immunoassay for quantitative determination of total immunoglobin E (tIgE) in human serum based on light-initiated chemiluminescent assay (LICA).Methods The LICA-tIgE assay was performed by incubating serum samples or calibrator with anti-human IgE antibody-coated chemiluminescet beads,biotinylated human IgE and streptavidin-coated sensitizer beads.The working conditions of this assay were optimized,analytical performance was detected and the correlation of tIgE results between LICA and Beckman Coulter IMMAGE 800 was evaluated.Results The precision of intra-assay and inter-assay (coefficient of variation) ranged from 5.50% to 7.73% and 6.45% to 9.90%,respectively.The functional sensitivity of this assay was 12.65 IU/mL.The recovery rates measured by adding IgE calibrators to human sera with different IgE concentrations were ranged from 104.15% to 109.37%.The disturbing rates measured by adding total bilirubin,hemoglobin and triacylglycerol to human sera with different IgE concentrations were ranged from-4.49% to 8.46%.Also,the tIgE results of 111 patients measured by LICA correlated well with those by Beckman Coulter IMMAGE 800 (r2 =0.959).Conclusion LICA developed in this study for detecting tIgE of human serum showed effective perfomance and could meet the basic requirements of clinical diagnostic reagents.

SELECTION OF CITATIONS
SEARCH DETAIL